EPA GmbH
About us
EPA GmbH was founded in 1988 as a sales company for frequency inverters. Due to the inseparable connection between electrical drive technology and EMC, the product portfolio was expanded in 1995 to include radio interference suppression components and the company began manufacturing EMC filters from its own development. In the meantime, EPA has become a well-known brand name when it comes to high-quality line filters and EMC products.
Driven by the steadily increasing component density of power electronics and the increased use of AC/DC sensitive residual current circuit breakers, the company has become the market leader in leakage current technology over the past 15 years through intensive research and development.
Planning, realization, commissioning, service, maintenance, formation of frequency inverters, production support and EMC measurements as well as devices for leakage current reduction/compensation plus individual consulting for customer-specific special solutions complete our product portfolio. This exceptional, cross-divisional competence in drives, EMC and leakage current technology makes EPA GmbH your partner in all matters.
Products & services

EPA NF-CF
EPA's NF-CF – Compact filters for frequency inverters and power drive systems Double deck design: high performance with a smaller footprint – reduced length with greater depth ✓ Very small dimensions (bookstyle) ✓ Very good attenuation properties ✓ Current ratings from 10 A up to 230 A

EPA NF-1ph-GSG
EPA's NF-1ph-GSG – Universal compact filters for noisy applications Whether it’s the NF-1ph-GSC, NF-1ph-FSE, or NF-1ph-GSG, there’s a compact filter to suit every performance requirement: as performance requirements decrease, the size of the filter can be reduced proportionally. ✓ Very high differential and common mode attenuation ✓ Current ratings from 1 A up to 30 A ✓ Single-phase, two-stage filter

EPA NF-1ph-GSC
EPA's NF-4-GSC – Universal compact filters for noisy applications an devices Whether it’s the NF-1ph-GSC, NF-1ph-FSE, or NF-1ph-GSG, there’s a compact filter to suit every performance requirement: as performance requirements decrease, the size of the filter can be reduced proportionally. ✓ High differential and common mode attenuation ✓ Current ratings from 1 A up to 30 A ✓ Single-phase, single-stage filter

EPA NF-4-GTR
EPA's NF-4-GTR – High performance mains RFI filters for machinery Two-stage enhancement of the EPA NF-4-FTN (single-stage RFI filter) for improved performance ✓ Low leakage current and very high attenuation ✓ Compact case style ✓ For current ratings from 8 A up to 200 A ✓ Three-phase with neutral conductor, two-stage

EPA LEAKCOMP® HP
EPA's LEAKCOMP® HP is used for leakage current compensation in power grids with servo drives and frequency inverters. ✓ Compensation of operational leakage currents up to 500mA (RMS) ✓ Increases the safety for devices on a RCD ✓ Use of RCDs with a residual current of 30mA or higher according to DIN VDE 0100-530 is possible ✓ Compatible with type B and B+ RCDs

EPA LEAKWATCH
EPA's LEAKWATCH leakage current measurement and analysis system makes leakage currents visible and thus assessable. ✓ Leakage current displaying in the Fourier analysis and as RMS value ✓ Leakage current evaluation in relation to the tripping characteristic of all market standard type B / B+ residual current devices ✓ Recording of switch-on / -off current spikes

LEAKCOMP® 1P
EPA's LEAKCOMP® 1P is used for leakage current compensation with single-phase frequency inverters and servo drives. ✓ Fixe value compensation of operational leakage currents up to 50 mA (RMS)! ✓ Increases the operational safety of systems ✓ Can be used on single-phase inverters with 30mA or higher possible according to DIN VDE 0100-530

LEAKCOMP® 1C
EPA's LEAKCOMP® 1C is used for leakage current compensation of single-phase devices. ✓ Fixe value compensation of operational leakage currents of 5 mA or 11 mA ✓ Increases the operational safety of systems ✓ Can be used on single-phase inverters with 30mA or higher possible according to DIN VDE 0100-530

EPA PECON+®
EPA's PECON+® is used for protective conductor monitoring for single-phase and three-phase power grids. ✓ For use of frequency inverters and servo drives ✓ The 3.5 mA limit may be exceeded according to the following standards: • DIN EN 50178 / VDE 0160 (AC 3.5 mA limit for electronic equipment) • DIN EN 61800-5-1 / VDE 0160-105 (AC 3.5 mA limit for power drive systems) • DIN EN 60204-1 / VDE 0113 (AC 10 mA limit for machines) ✓ For networks with rated voltages of 115 VAC up to 400 VAC with or without neutral

EPA RCCB type B / B+
EPA's RCCB Type B / B+ from EPA - the AC/DC-sensitive residual current circuit breaker with special characteristic for drive technology ✓ Tripping frequency response for the protection of systems with frequency inverters ✓ Rated residual current 30 mA for contact protection according to the selection recommendations of DIN VDE 0100-530 ✓ Rated residual current 0.3 A for fire protection according to the guidelines of VDS 3501 ✓ Safety through detection of smooth DC residual currents and AC residual currents up to 150 kHz

EPA AF-BCR
EPA's AF-BCR - the absorption filter in order to avoid motor bearing damages ✓ Absorption tunnel® 3 x 11 mm, 3 x 18 mm or 3 x 44 mm ✓ Reduces maintenance and downtimes ✓ Easy to retrofit ✓ Flexibly combinable with other RFI filters

EPA NF-DAR / NF-KC-DAR
EPA's NF-DAR / NF-KC-DAR - the Leakage current reduction filters with and without internal EMC filter ✓ For suppression of unwanted leakage currents ≥ 2 kHz ✓ Increases the safety for devices with an RCD ✓ EMC improvement ✓ For nominal currents up to 800 A

EPA PreLEAK® TECHNOLOGY - NF-KC-LKY
EPA's NF-KC-LKY - Line filters with PreLEAK® TECHNOLOGY for a safe operation on the RCD ✓ Unique technology worldwide ✓ No faulty RCD trippings while switching machines and systems on or off ✓ No faulty RCD trippings while connecting and disconnecting the CEE plug ✓ Very good attenuation properties

EPA DiffDi®
EPA's DiffDi®, a system for differential current diagnosis, makes leakage currents visible and thus assessable. ✓ Differential current diagnosis on frequency-controlled drives ✓ Investigation of high-frequency currents and their effects on the motor (motor damage due to bearing currents)